Maintenance And Service; Maintenance And Cleaning - CST/BERGER 58-iLMXL Manual De Instrucciones

Ocultar thumbs Ver también para 58-iLMXL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
If the distances are the same, the measuring tool is in calibration.
If the difference between the two points is greater than half of the spec-
ified accuracy, the measuring tool must be calibrated.
Checking the Horizontal Line from Side to Side (see Fig. C2)
– Set up the measuring tool approx. 2.5 m from a wall that is at least
5 m long.
– Project the laser cross laterally 30 cm from one corner. Mark point
(A) alongside the horizontal laser line 2.5 m from the intersecting
point of the laser cross.
– Rotate the measuring tool so that the laser cross is projected 4.6 m
away from the first projected laser cross.
The deviation of the horizontal laser line from the previously marked point
(A) should not be greater than half of the specified accuracy.
Note: The measuring tool is factory-calibrated and requires no further
calibration. Should calibration of the measuring tool be necessary,
please refer to your dealer or an authorised service agent for Bosch
power tools.

Maintenance and Service

Maintenance and Cleaning

Keep the measuring tool clean at all times.
Do not immerse the measuring tool into water or other fluids.
Wipe away debris or contamination with a dry, soft cloth. Do not use
cleaning agents or solvents.
Regularly clean the surfaces at the exit opening of the laser in particular,
and pay attention to any fluff of fibres.
If the measuring tool should fail despite the care taken in manufacturing
and testing procedures, repair should be carried out by an authorized
after-sales service centre for Bosch power tools.
22 | English
1 609 929 T56 • 24.2.09

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido