9.
TROUBLESHOOTING TABLE
This table facilitates identification of the cause of the defect. The manufacturer recommends that the technical service department
is contacted in good time, to obtain instructions for operating and/or adjusting in condition of maximum safety.
RAVAGLIOLI S.p.A. will not accept any responsibility for damage to people, animals and objects caused by manoeuvres by
unauthorised and unqualified personnel.
9.1 Hydraulic wheel free jack
PROBLEMS
The jack does not slide
smoothly and load is
unstable.
The pump works but is
not supplying oil .
The jack works
unloaded but not when
loaded.
The pump reaches but
will not hold maximum
pressure.
9.2 Pneumatic-hydraulic wheel free jack
PROBLEMS
The pump does not start
or stops during the
operation (before reaching
the maximum pressure).
The pump works but does
not send oil
Low capacity
The pump does not reach
the maximum pressure.
The pump reaches the
maximum pressure but
does remain under
pressure.
Excessive oil leaks from
the air drainage.
Oil tank gets up to
pressure with air and oil
leaks from the valve.
Pump continues to pump
even after the pedal has
been released.
After a period of disuse,
the pump does not start.
J22
CAUSES
a) Sliding rollers do not rest properly
(a roller does not rest on the platform)
a) Low oil level.
a)
Load exceeds allowed limit.
b)
Piston seals damaged.
Pressure relief valve leaking.
c)
a)
Check hydraulic connections.
b)
Check ball of pressure relief valve.
c)
Oil leak on connected equipment.
CAUSES
a)
Return spring broken
Air loss, check the piston seal
b)
Oil level low
a)
b)
Pump does not prime
Tank not ventilated
a)
Insufficient air capacity
b)
Hydraulic causes:
c)
- Check that the oil filter is not blocked
- Air in the hydraulic circuit
- Check that the ball of the suction valve
works properly
Check the air pressure
a)
Valve or gaskets faulty or dirty
b)
a)
Check hydraulic connections
Dirt under the pedal
b)
The ball of the delivery valve
c)
d)
Leakage on the apparatus connected
a) Gaskets faulty
Air leakage from the gaskets
a)
b
Tank too full of oil
Gaskets faulty
a)
Air valve spring broken or too weak
b)
a) Gaskets faulty
0432-M001-1
REMEDIES
a) Check rest points and adjust pullout
retaining screws (see procedure in par.
"INSTALLATION")
a) Top up oil level.
a)
Check.
b)
Replace seals.
Contact authorised technical service.
c)
a)
Tighten if necessary.
b)
Clean or replace.
c)
Repair and check for leaks.
REMEDIES
a)
Replace
Replace if faulty
b)
Top up oil
a)
b)
Operate the pedal in the "RELEASE area
at the same time as the air valve to start
the motor.
- Bleed the air out
- Pressurize the tank
CAUTION
Max. pressure 0.5 Bar (7 P.S.I.)
- Remove and clean
Ventilate tank through the screw on the
a)
plug
Capacity should be 250 Lt/minute
b)
- Clean or replace
c)
- Bleed air from the circuit
- If necessary add a copper washer or
replace coupling if the housing is worn.
7 bar (100 P.S.I.) is required
a)
Clean or replace
b)
a)
Tighten if necessary
Clean
b)
Replace gaskets
c)
d)
Repair and check seal
a) Replace
Replace gaskets
a)
b)
Check the level
Replace
a)
Replace
b)
a) Replace
33