[en]
Fountain Units
3.1
CONFIGURATION DMX/RDM
A DMX/RDM controller with its respective software is required, with the purpose
of configure the channels and directions of DMX that we will use in our equipment
in a bidirectional way. Almost, we can check other parameter like:
Code
$8008
$8009
Therefore, the desired DMX address can be assigned to each pump at the desired
time
Example of DMX address assignation on V:Nano 512:
Menu RDM DMX 1 > Device list > pump ID > DMX address.
3.2
OPERATION
-
The operation of the unit will depend on the control system installed, which is
not supplied with this unit.
A DMX controller is required for the operation of the unit.
-
The range of DMX channels with which the pump works goes from 0 to 255,
having the value 10 as a minimum height of the pump jet, and 255 as the
maximum height.
WARNING: The maximum work cycles of the pump are 60 starts/hour.
WARNING: Use the equipment only to pump water with the characteristics described
in section 1.2.
WARNING: Do not operate the pump until the water level is 20 cm above the highest
point of the pump.
3.3
MAINTENANCE
WARNING: Risk of dead due to electric shock. Disconnect the equipment from the
main power supply before performing any maintenance.
For the maintenance of the components made of stainless steel, see the manual
attached.
16
INSTALLATION, OPERATION AND MAINTENANCE MANUAL; DMX VARIABLE PUMP S
Variable
TARGET TEMP
TARGET VOLT
Function
Temperature reading sensor
Voltaje reading sensor