Technical Specifications; Faqs - Astralpool DMX VARIABLE PUMP S Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

It is highly recommendable to activate the device at least once a week to check the
proper operation.
Clean the pre-filter of the pump at least once a week.
NOTE: The cleaning frequency of the pump pre-filter will depend on the conditions
in which the installation is.
4

TECHNICAL SPECIFICATIONS

Input Voltage
Power
Water outlet
Protection IP rating (IEC 60529)
Pump control
24V Power supply cable length
DMX cable length
5

FAQS

Question
¿Why the water jet outlet is defective?
(speed, height)
¿Why the pump don't switch on?
INSTALLATION, OPERATION AND MAINTENANCE MANUAL; DMX VARIABLE PUMP S
2,5 m DMX IN / 2,5
m DMX OUT
Answer
Check the correct working of the
pump.
Check inside the nozzle. The nozzle
should be empty of stools and without
obstructions.
Check the obstruction of pre-filter.
Check the DMX signal.
Check the electric installation and wiring.
Check the DMX signal.
Check the state of the electrical
protections.
Check that the impulsion is not
obstructed.
Fountain Units
24 V DC
100W
G 1 ½" M
IP-68
DMX512
10 m
17
[en]

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

67410

Tabla de contenido