5.1. Controls
(See jacket flap)
5.1.1. Device
[1] On/Off Power switch
With this switch the Sonopuls 492 is switched
On/Off.
[2] Type number/warning sticker
Provides information on the apparatus, such as
type and serial number, as well as connection
data such as mains voltage and maximum cur-
rent consumption.
[3-1] Connector for mains adapter
[3-2] Connector for remote control
For connection of the optional remote control.
[4-1] Connection Patient Cable Electrotherapy
[4-2]Connection Ultrasound treatment head
5.1.2. Control panel
[5] Battery indicator
There are four possibilities:
• Lights green
: battery is fully charged
• Lights blinking
green
: battery partial discharged,
• Lights yellow
: battery insufficiently charged,
• Off
: no battery present, battery ful-
[6] Mains adapter indicator
This lamp indicates that the mains adapter is
connected to the power supply.
[7] Therapy options
Selection button for electrotherapy, current
channel selection, linked current channels, in-
terval between program steps, ultra sound
therapy and combination therapy.
[8] Selection button current waveform
This button is to select the different current wave-
forms.
[9] Selection button for
Carrier wave, pulse width, microcurrent fre-
quency, interferential current type, alternating
mode (High Voltage and Microcurrent) and ul-
trasound frequency
connect mains adapter
therapies disabled, connect
mains adapter
ly discharged or defective,
connect mains adapter
CHAPTER 5 - OPERATION
[10] Selection button for
Beat frequency, phase interval, burst frequency
(Russian stimulation), vector position, balance
position, Diadynamic current waveforms, modu-
lation frequency (spectrum) and ultra sound
duty cycle.
[11] Selection button for
Modulation time (spectrum), duty cycle (Rus-
sian stimulation), burst frequency (TENS) and
treatment step number (protocols)
[12] Selection button for
Surge programme, vector rotation time and
treatment timer
[13] Selection button for
Current channel, CC/CV mode, polarity and ul-
trasound unity
[12]+[13] Emergency stop.
Pressing buttons [12] and [13] simultaneously
will terminate all active treatments.
[14] Accept button
To accept the current waveform selection, the
pre-programmed protocols and to start the
surge programs.
[15] Memory button
To generate the memory functions and to re-
call and store programs
[16] Central controller
Controller to adjust all settings and parameters.
[17] Intensity controller
Controller to adjust the current intensity in chan-
nel 1 and 2. In 4-pole mode (interferential cur-
rents) this controller adjusts the intensity in both
channels together.
[18] Intensity controller ultrasound
Controller to adjust the intensity for ultrasound.
[19] Interval symbol
The symbol
indicates the interval between
two program steps of a sequential program.
33