Steam Requirements (Steam Heat Option Only) - Alliance Laundry Systems UW35PV Instalación/Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Steam Requirements
(Steam Heat Option Only)
WARNING
Never touch internal or external steam
pipes, connections, or components. These
surfaces can be extremely hot and will
cause severe burns. The steam must be
turned off and the pipe, connections, and
components allowed to cool before the pipe
can be touched.
Steam inlet connection, in (mm)
Number of steam inlets
Recommended pressure, psi (bar)
Maximum pressure, psi (bar)
F232084
SW014
UWPV Pocket Hardmount
Steam Supply Information
35
1/2" (DN13)
1
30 – 80
(2.0 – 5.5)
80 (5.5)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For washer-extractors equipped with optional
steam heat, install piping in accordance with
approved commercial steam practices. Steam
requirements are shown in the table below.
Failure to install the supplied steam
Note:
filter may void the warranty.
60
80
1/2" (DN13)
1/2" (DN13)
1
1
30 – 80
30 – 80
(2.0 – 5.5)
(2.0 – 5.5)
80 (5.5)
80 (5.5)
Installation
100
125
1/2" (DN13)
3/4" (DN19)
1
1
30 – 80
30 – 80
(2.0 – 5.5)
(2.0 – 5.5)
80 (5.5)
80 (5.5)
31

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Uw80pvUw125pvUw60pvUw100pv

Tabla de contenido