Installation
Steam Requirements
(Steam Heat Option Only)
WARNING
Never touch internal or external steam
pipes, connections, or components.
These surfaces can be extremely hot and
will cause severe burns. The steam must
be turned off and the pipe, connections,
and components allowed to cool before
the pipe can be touched.
For washer-extractors equipped with optional steam
heat, install piping in accordance with approved
commercial steam practices. Steam requirements are
shown in Table 7.
NOTE: Failure to install the supplied steam filter
may void the warranty.
Cabinet Freestanding
Steam Supply Information
Steam inlet connection
Number of steam inlets
Recommended pressure
Maximum pressure
34
SW014
135
250
3/4 in.
1 in. (DN25)
(DN20)
(25.4 mm)
(19.05 mm)
1
1
30 – 80 psi
30 – 80 psi
(2.0 – 5.5 bar)
(2.0 – 5.5 bar)
80 psi
80 psi
(5.4 bar)
(5.4 bar)
Table 7
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Air Requirements
Air supply requirements are shown Table 8, Table 9
and Table 10.
Standard 135 Pound Cabinet Freestanding
Air Supply Information
Inlet size
Recommended pressure
Average consumption
Table 8
Standard 250 Pound Cabinet Freestanding
Air Supply Information
Inlet size
Recommended pressure
Average consumption
Table 9
250 Pound Cabinet Freestanding with Tilt Air
Supply Information
Inlet size
Recommended pressure
Average consumption
Table 10
1/4 in. (DN8)
(6.35 mm)
25 – 100 psi
(1.7 – 8 bar)
0.1 CFM
(.003 CMM)
1/4 in. (DN8)
(6.35 mm)
25 – 100 psi
(1.7 – 8 bar)
0.1 CFM
(.003 CMM)
1/4 in. (DN8)
(6.35 mm)
80 – 100 psi
(5.5 – 6.9 bar)
1.5 CF/tilt
(.05 CM/tilt)
F232102