Fekabox 110
G2"
DN50/110
G2"
Key to Symbols
Connection of delivery pipe or emergency outlet
Collection pipe inlet
Outlet of power cables and float cables
5.

TANK INSTALLATION

The lifting stations of the Fekabox 110 series have various inlet and outlet possibilities for the pipes. Depending on the type of
installation and on the local standards in force it may be necessary to provide a siphon, a non-return valve on the pipe connecting to
the public/private sewer network or to other ducts. Always refer to the local and/or national regulations, laws and standards in force.
Anyway it is recommended to install check valves and interception valves upstream and downstream from the station. An example of
installation is shown in chapter 4.
All the ducts must be installed in such a way that they are not stressed. The ducts must not exert stress on the
station. Check that the electropump is securely fixed to the pipes and that all the hydraulic connections are
tightened and watertight.
Where necessary provide suitable means for avoiding the transmission of vibrations and for protecting the pipes against the
formation of ice.

5.1 Placing the tank inside the building

The tank may be laid on the floor, under the ground or housed in a masonry pit. Fig.1, Fig.3
In any case the surface on which it is laid must be perfectly horizontal and it must be ensured that the whole bottom of the
tank is in contact with the surface.
For Fekabox 110 the cover of the tank is trafficable (max. weight 100 Kg, see fig. 2).
In indoor installations (garage, basement, technical room), the tank must be fixed to the ground using the slots
provided to prevent rotations, as indicated in figure 4.
horizontal outlet
vertical outlet
DN50
ENGLISH
DN50/110
Connection of ventilation pipe
Recyclable material
21
DN40
emergency drain
DN50/110