MAINTENANCE
After starting up the plant, it is advisable to inspect and clean it, especially the no return valve, about every three months. This
interval may be increased after the first inspections have given a favourable outcome.
Clean the pump accurately, removing any foreign bodies stuck in the intake grille and check that the float moves freely. If necessary,
remove the pump from the tank.
It is recommended to clean the system at least once a year with running water, operating the pump repeatedly.
10. TROUBLESHOOTING
FAULTS
1. Water is overflowing from the
tank and the pump is not
working.
(In this situation the alarm, if
installed,
must
intervene.
Otherwise
check
the
system installation instructions.)
2. The
alarm,
if
installed,
intervenes, but the system
operates regularly.
11. DISPOSAL
This product or any part of it must be disposed of correctly:
1.
Use public or private local systems for waste collection.
2.
If that is not possible, contact Dab Pumps or the nearest authorised service workshop.
CHECK
(POSSIBLE CAUSES)
A. Delivery pipe blocked..
B. The pump is not correctly connected to the
delivery pipe.
C. No return valve blocked.
alarm
D. Interception valve closed.
E. Pump characteristics are insufficient.
F. The pump intake grille is blocked.
G. The impeller is worn or blocked by foreign
bodies.
A. Check the exact position of the alarm float.
ENGLISH
25
REMEDY
A. Remove the obstructions.
B. Check that the pump slide is at its full
limit (only for 280 l tanks).
C. Clean the valve.
D. Open the valve.
F.
Remove the obstructions.
G. Remove the obstructions.
A. Repeat the checking and installation
operations.