CoolAir SPX1200I
I
NOTE
Configuration mode can still be activated if the low voltage cut-out has
switched off the system and only residual voltage is available.
7.1

Entering and exiting configuration mode

➤ Press and hold the
➤ Press and hold the
✓ The display shows the symbol
✓ The parking cooler switches to configuration mode.
✓ The display shows "P.01" and the symbol
➤ Scroll through the menu by pressing the
desired menu item.
➤ Press the
➤ Press and hold the
7.2
P.01: Low voltage shut-down
The battery monitor protects the battery against discharging excessively.
A
NOTICE!
If the unit is switched off by the battery monitor, it means the battery charge
level is low. Avoid repeated starting or using electrical equipment. Make sure
that the battery is recharged. As soon as the required voltage is available again,
the system can be operated again.
If only the power supply voltage specified here is available to the parking cooler,
the system is switched off.
➤ Switch to configuration mode (chapter "Entering and exiting configuration
mode" on page 13).
✓ The display shows "P.01" and the symbol
➤ Press the
✓ The current setting is displayed.
➤ Use the
down.
The low voltage shut-down setting can be adjusted in 0.1 V increments from
20.0 V to 23.5 V.
EN
button.
button for longer than 3 s.
.
button to open the desired menu item.
button for longer than 3 s to exit configuration mode.
button to change the setting.
or
button to select the voltage level for low voltage shut-
Configuration of unit software
flashes.
or
button to select the
flashes.
13