The faults that may be produced in the sauna if it is correctly installed are minimal or null in domestic use. Thus, the following list is essentially of those faults
that may be produced by improper installation of the sauna or after years of use. The majority of the faults considered are unusual, although we think it
important to show them in the following table. The long-term faults that may be produced will be with the electrical equipment, since the booth(if properly
assembled) will not provoke faults. If any element has broken due to accident, replace it.
PROBELMS
SYMPTOMS
The sauna does not go above 50ºC Safety contactor faulty
The differential of the property is
tripped
The sauna does not turn on
Temperature rises without control Blocked contactor activated
The light does not work
The protective circuit breaker is
Tripped.
38

POSSIBLE FAULTS

PROBABLE
CAUSE
Thermohygrometer faulty
Manual regulator level incorrect
Element melted
Interior sensor faulty
Relays faulty
Connection incorrect
Excess of water on the heater
Element connected to the chassis
There is no tension to the connection
Security sensor faulty
Control panel fuse blown
Blocked contactor deactivated
Connection incorrect
Transformer faulty
Manual regulator maximum level
Bulb burned out
Connect correctly
Overheating of the line to the sauna
Cross in the heater
Resistance crossed
VERIFICATION OF
THE CAUSE
Inspection
Inspection
Inspection
Heater inspection
Verify the sensor part
Check manual
Disconnect the sauna
Verify the resistance
Verify circuit breaker
Verify thermofuse
Control panel inspection
Control panel contactor inspections
Check manual
Control panel contactor inspection
Inspection
Verify
Check manual
Check manual
Inspect element
Verify the resistance
SOLUTION OF THE
PROBLEM
Put pressure on door
Replace
Monitor closely
Replace
Replace
Connect correctly
Wait 24 hours. Connect again
Remove and replace resistance
Activate
Replace
Replace fuse in the panel
Consult your distributor
Connect correctly
Consult your distributor
Regulate correctly
Replace
Connect correctly
Correct the error on the line
Specialist correct the error
Replace