1
Connect the electrofusion machine to
the supply voltage.
ü Mains connection LED display
lights up.
2
Connect the connecting cable for
electrofusion coupling to the
electrofusion sleeve coupling or the
electrofusion tape for anchor point.
ü Ready for welding LED display
lights up.
18014400775144843-1 © 10-2017
967.779.00.0 (00)
3
Press the start button.
ü Welding procedure LED display
lights up and the Ready for
welding LED display
4
After approx. 80 seconds, the
welding is complete and the sleeve
connection plug can be unplugged.
00:01:20
ü Welding procedure LED display
goes out and the Welding
complete LED display
up.
Result
ü Welding has been performed correctly.
EN
goes out.
lights