Optional Default Lock; Idle Opening Steps Over Default; Idle Closing Steps Under Default; Out-Of-Idle Opening Steps Over Default - A.E.B. AEB215 Manual De Uso

Tester palmar
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

OPTIONAL CONFIGURATIONS
WARNING: THE FUNCTIONS DESCRIBED IN THIS PAGE MUST BE MODIFIED ONLY
WHEN NECESSARY. THE BASE CONFIGURATION IS OPTIMIZED FOR THE
MAJORITY OF VEHICLES. CONTACT OUR TECHNICAL SUPPORT DEPARTMENT
WHEN ASSISTANCE IS REQUIRED.
OPTIONAL DEFAULT LOCK (Fig. 47)
The locked default option is to be utilized only in particular cases
when the vehicle is malfunctioning.
DEFAULT LOCKED VALUE (Fig. 48)
This is the number of steps at which the default is locked.
This function is displayed only if the "DEFAULT LOCKED VALUE" is
enabled.
IDLE OPENING STEPS OVER DEFAULT (Fig. 49)
This is the maximum number of steps towards opening that the stepper
motor can perform in idle mode.
EXAMPLE: if the stepper's idle default value is 100, entering 30 as
the number of idle steps over default will permit the stepper motor to
open up to 130 steps.
IDLE CLOSING STEPS UNDER DEFAULT (Fig. 50)
This is the maximum number of steps towards closing that the stepper
motor can perform in idle mode.
EXAMPLE: if the stepper's idle default value is 100, entering 30 as
the number of idle steps under default will permit the stepper motor
to close down to 70 steps.

OUT-OF-IDLE OPENING STEPS OVER DEFAULT

(Fig. 51)
This is the maximum number of steps towards opening that the stepper
motor can perform in out-of-idle mode.
EXAMPLE: if the stepper's out-of-idle default value is 100, entering
30 as the number of out-of-idle steps over default will permit the
stepper motor to open up to 130 steps.

OUT-OF-IDLE CLOSING STEPS UNDER DEFAULT

(Fig. 52)
This is the maximum number of steps towards closing that the stepper
motor can perform in out-of-idle mode.
EXAMPLE: if the stepper's out-of-idle default value is 100, entering
30 as the number of out-of-idle steps under default will permit the
stepper motor to close down to 70 steps.
If the Cut-Off or the full throttle option is enabled, the LEONARDO
ignores the above limitations during those modes.
Is215-2 Rev. 110105-2
LEONARDO

OPTIONAL DEFAULT LOCK

ENGAGED
Fig. 47
DEFAULT LOCKED VALUE
80
Fig. 48
IDLE OPENING STEPS
OVER DEFAULT
25
Fig. 49
IDLE CLOSING STEPS
UNDER DEFAULT
25
Fig. 50
OUT-OF-IDLE OPENING
STEPS OVER DEFAULT
40
Fig. 51
OUT-OF-IDLE CLOSING
STEPS UNDER DEFAULT
40
Fig. 52
55 - 188

Publicidad

Tabla de contenido
loading

Tabla de contenido