OPERATION
3. Hinge open recovery tank to access batteries.
Make sure recovery tank is empty before opening
(Figure 26).
FIG. 26
4. Check fluid level (A) in each battery cell. Do not
charge batteries unless fluid is slightly covering
battery plates (B). If needed, add just enough
distilled water to slightly cover plates. DO NOT
overfill. Batteries can overflow during charging due
to expansion. Replace cell caps before charging
(Figure 27).
A
FIG. 27
5. Plug charger DC output connector to battery
connector located near battery compartment. Flip
up tank support stand and rest tank on stand
(Figure 28).
FIG. 28
NOTE: Once charger is connected to machine,
machine becomes inoperable.
16
B
Home
Find... Go To..
6. Plug charger power supply cord into a grounded
wall outlet (Figure 29).
Grounded
3 Hole Outlet
Ground Pin
(120V)
FIG. 29
7. Charger will automatically begin charging and
automatically shut off when fully charged.
8. When disconnecting charger, always unplug
charger from wall outlet first.
9. Recheck battery fluid level after charging. If
needed, add distilled water to bring level to bottom
of sight tubes. Be certain to replace cell caps
securely and to wipe off the top of batteries with a
clean cloth.

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow the daily, weekly and monthly maintenance
procedures.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
WARNING: Disconnect Battery Cables Before
Servicing Machine.
ATTENTION: Contact an Authorized Service
Center for machine repairs. Machine repairs
performed by other than an authorized person will
void your warranty.

DAILY MAINTENANCE

(Every 4 Hours of Operation)
1. Remove and clean pads/brushes. Never use
soiled pads when cleaning. Replace pads when
they become loaded with residue.
2. Remove and clean lint from float shut–off screen
located in recovery tank (Figure 30).