8.3 NORMAS ATENDIDAS
Normas de seguridad
Compatibilidad
eletromagnética
(EMC)
Normas de construcción mecánica
8.4 CERTIFICACIONES
Certificaciones (*)
UL y cUL
E184430
CE
IRAM
C-Tick
EAC
Link: http://ww2.eagle.org/en/rules-and-resources/type-approval-database.html
Accediendo al link, hacer click en "Select Option" y seleccionar "Data Search".
ABS
En la nueva pantalla, en el espacio "Certificate Number" debe ser colocado el número de certificado: 15-
RJ2890495. Hacer click en "Search".
Functional Safety
Función STO, con certificado emitido por el TÜV Rheinland.
(seguridad
funcional)
(*) Para información actualizada sobre certificaciones consultar a WEG.
UL 508C - power conversion equipment
Nota:
Suitable for Installation in a compartment handling conditioned air
UL 840 - insulation coordination including clearances and creepage distances for electrical equipment
EN 61800-5-1 - safety requirements electrical, thermal and energy
EN 50178 - electronic equipment for use in power installations
EN 60204-1 - safety of machinery. Electrical equipment of machines. Part 1: general requirements
Nota: el montador final de la máquina es responsable por instalar un dispositivo de parada de
seguridad y uno de sección de la alimentación
EN 60146 (IEC 146) - semiconductor converters
EN 61800-2 - adjustable speed electrical power drive systems - part 2: general requirements -
rating specifications for low voltage adjustable frequency AC power drive systems
EN 61800-3 - adjustable speed electrical power drive systems - part 3: EMC product standard
including specific test methods
CISPR 11 - Industrial, scientific and medical (ISM) radio-frequency equipment – electromagnetic
disturbance characteristics - Limits and methods of measurement
EN 61000-4-2 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 2: electrostatic discharge immunity test
EN 61000-4-3 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 3: radiated, radio-frequency, electromagnetic field immunity test
EN 61000-4-4 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 4: electrical fast transient/burst immunity test
EN 61000-4-5 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 5: surge immunity test
EN 61000-4-6 - electromagnetic compatibility (EMC)- part 4: testing and measurement techniques -
section 6: Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-11 - Testing and measurement techniques - Voltage dips, short interruptions and
voltage variations immunity tests
EN 60529 - degrees of protection provided by enclosures (IP code)
UL 50 - enclosures for electrical equipment
IEC 61800-5-1 – adjustable speed electrical power drive systems - part 5-1: safety requirements -
electrical, thermal and energy
Nivel 10 Hz a 57 Hz - 0,075 mm de rango 57 Hz a 150 Hz - 1g
Observaciones
Especificaciones Técnicas
CFW-11 | 8-7
8