Power Switch - Bosch Rexroth SB356 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
3 609 929 B67/2008-11 | SB356

Power switch

5 A max
Setting
mark
Fig. 8: Power switch
On the SB356, the trigger behavior of the Q0
power switch must be assigned as follows:
Table 3:Trigger behavior of power switch
Voltage
380 V
Group 1
400 V
(G1)
420 V
440 V
Group 2
460 V
(G2)
480 V
Group 3
500 V
(G3)
Power setting on Q0
5.0 A
4.8 A
4.5 A
4.3 A
4.1 A
4.0 A
3.8 A
Bosch Rexroth AG
Mains connected loads
(nominal values)
The required connected load of the SB356
system box depends on the number and size
of the tightening channels to be operated. As,
however, an SB356 must always be
considered as fully equipped, we
recommend configuring the connected load
for a fully equipped SB356 system box (see
chapter "15 Technical data").
If the SB356 system box is not fully equipped
and fused and it is certain that they will not be
retrofitted with additional tightening
channels, the mains connected load can be
configured in accordance with Table 4.
Tab. 4:3-phase connection
Number of LT35x in SB356
1*
2
LT353
500
700
with
VA
VA
EC302
LT353
600
950
1250
with
VA
VA
EC303
LT354
700
1200
1700
with
VA
VA
EC304
LT355
1200
1800
2500
with
VA
VA
EC305
35/124
3
4
5
6
900
1050
1200
1350
VA
VA
VA
VA
1500
1750
2000
VA
VA
VA
VA
2100
2500
VA
VA
VA
VA

Publicidad