possible use the racores of the right as well as the left ones (according to
convenience of the installation), logically the two racores that are not used
will have to be covered with their corresponding stoppers. "Likewise a racor of
½" is present" for the insertion of the probe of temperature for the safety
system and other two racores of 3/8 " that are the entry and exit of the coil of
stainless steel. of the safety system.
It is very important, that both the connection and the circuit of heating, are
realized by professional staff.
The circuit is to be provided with the corresponding measures of safety.
The model must never be established for boiler, must be installed in a circuit
with accelerating bomb.
It is advisable to install the thermostat of on-off, of the bomb nearby possible
mas to the exit of warm water of the large water deposit.
Once the chimney is connected to the circuit of heating, we will fill the circuit
and will prove the functioning during 2 - 3 days, rejecting the possibility of
escapes. Verified this we will be able to re-dress the chimney
It is necessary to design a circuit of heating that when it is functioning on its
highest efficiency, water can´t be warmer than 90ºC to avoid werheating and
werpressure.
For the case when the water of the circuit reaches high temperatures that
could provoke a heat excess (when water Stara to boil), the model includes a
safety system that consists of a coil of stainless steel, that this in touch with the
water of the boiler and that by means of the opportune connections removes
the heat excess. (To see basic scheme of installation). It is recommended that
the circuit should possess other systems to remove the heat, as radiator of "
heat escape ", a valve of thermal unload, a capture of cold water ... etc.
The circuit will have to possess a key of purge in it low part to facilitate to
empty it.
Σύνδεση µε τον κύκλωµα θέρµανσης.
Στην οροφή αυτού της εστίας, υπάρχουν αριστερά και δεξιά, από µία αναµονή της
GR
1''( συνολικά 2) που χρησιµοποιούµε για να συνδέσουµε την είσοδο στο κύκλωµα
της θέρµανσης (αποστολή) και άλλες δύο αναµονές της 1'' στο κάτω µέρος των
πλαϊνών τοιχωµάτων (1 σε κάθε πλευρά) για να συνδεθεί η επιστροφή από το
κύκλωµα θέρµανσης. Μπορούν να χρησιµοποιηθούν τόσο οι αναµονές που
βρίσκονται δεξιά όσο και αριστερά ( για την διευκόλυνση της εγκατάστασης), και
λογικά οι δυο αναµονές που δεν θα χρησιµοποιηθούν θα πρέπει κλείσουν µε τα
αντίστοιχα καπάκια τους. Μπορούν να χρησιµοποιηθούν και οι τέσσερις εάν είναι
απαραίτητο. Εάν χρησιµοποιηθούν δυο συνίσταται αυτές να είναι χιαστή (δηλαδή η
αριστερά επάνω µε την δεξιά κάτω). Επίσης στην οροφή υπάρχουν δύο αναµονές της
0
1/2" για την εισαγωγή αισθητήρα θερµοκρασίας (ή θερµοστατικής βαλβίδας 95
C)
για το σύστηµα ασφαλείας, και για την βαλβίδα υπερπίεσης 3 bar. Τέλος υπάρχουν