36
ENGINE OPERATION
3
1. Neutral (N)
2. Control lever
3. Fully open (Forward)
4. Fully closed (Fully closed)
5. Free throttle lever
6. Main switch key
7. Stop switch
5. Turns the main switch key to START
position. Then, continuously push the
key to operate the choke.
7
ENON00503-0
Note
Choke operation is not necessary if the
engine is warm.
1. ON
2. START
3. OFF
4. Push operate choke knob
6. Stop pushing the key when the engine
has started.
The key returns to the original position,
automatically.
1
2
N
5
4
6
7
ENOF00870-0
1
2
3
4
ENOF00871-A
7. Returns the Free accel lever to close
position.
8. Confirm warning lamp light up and
then go off after engine has started.
1. Warning lamp
9. Check the cooling water from cooling
water check port.
ENOM00042-B
Emergency starting
ENOW00099-A
WARNING
When the emergency starter rope is used
for starting engine;
Start in gear protection does not work.
Be sure to shift is at neutral position.
Otherwise the engine will move the boat
immediately and cause personal injury.
Be careful that your clothes or other
items do not get caught in the rotating
engine parts.
To prevent accident and injury by rotat-
ing parts, do not re-attach flywheel
1
ENOF00851-A
ENOF01212-0