6. TROUBLESHOOTING
Problem
Possible cause
The motor does not
The battery does not work
operate
any longer.
The metallic tubes, floor
brushes, batteries or the
device itself are not properly
assembled.
The dust tank is full.
Suction power has
The filter has too much dust.
been reduced.
The electric rotary brush inlet
is obstructed or the brush is
blocked.
Insufficient operating
Insufficient charge time.
The battery is old.
time after charge.
7. Error codes
Code
Problem
The device turns off and does not
E1
charge
E2
The device does not charge
E2
The device does not charge
The device turns off
The device turns off and displays
E3
E3
E5
The device turns off and displays
E5
42
ROCKSTAR 900 ULTIMATE
Solution
Charge the vacuum cleaner.
Make sure all parts of the device
are correctly assembled.
Clean dust.
Clean or replace the filter.
Clean the dust inside the electric
rotary brush.
Fully charge the battery following
the instructions in this manual.
Batteries are easily recycled. Go
to the closest maintenance point
and buy new batteries.
Cause
Short-circuit
The charger's voltage is below
36.3 V
The charger's voltage is below
32.1 V
Low battery
The motor short-circuits when
battery is low
Main motor overload (second
level)
The device turns off and displays
E6
E6
The device turns off and displays
E9
E9
The device stops working or does
E7
not turn on and shows E7
E8
The device turns off and displays
E8
High-efficiency
The device stops working or does
filter indicator
not turn on
blinks
The indicator
Works normally
blinks
The indicator
Works normally
blinks
The indicator
Long brush and motor stop
blinks
working
Note:
The low battery warning will disappear when the charger is disconnected.
Low battery error (excluding shut down due to low battery), will stop after 6 seconds. If not,
press the on/off button to stop it.
Communication or NTC error: It will stop after 60 seconds.

8. TECHNICAL SPECIFICATIONS

Product reference: 05706
Product: Rockstar 900 Ultimate
100-240V ~ 50-60 Hz 0.8 A
Motor rated power: 550 W
Brush rated power: 50 W
Made in China | Designed in Spain
ENGLISH
Main motor overload
Temperature too high or low
Battery fault (first level)
NTC error (thermistor short-
circuit)
High-efficiency filter not installed
The dust tank o the inlet filter is
blocked
Long brush full of hair
Blocked long brush