Genius G60 Manual Del Usuario página 13

Ocultar thumbs Ver también para G60:
Tabla de contenido

Publicidad

ENGLISH
3) Effect the 3rd OPEN command to establish the point at
which
the start of deceleration is required.
4) Effect the 4th OPEN command to establish the point of stop-
ping in opening, or wait until the automatic system detects
the opening end travel and stops.
5) Effect the 5th OPEN command: the automatic system starts
the closing movement.
6)
Effect the 6th OPEN command to establish the point at
which the start of deceleration is required.
7) Wait until the door reaches the ground stop and the operator
stops.
If the learning procedure was successful, the courtesy light stops
flashing and remains on for 5 seconds.
During these 5 seconds, in order to reduce the load on the re-
lease system, OPEN pulses can be sent within 2 seconds of each
other to reverse the carriage. A pulse equals 5 mm travel.
N.B.: Carriage reversing is only visible during normal operation
of the automatic system
AUTOMATIC LEARNING WITH LOGIC "A" (AUTOMATIC)
Hold down the SET-UP pushbutton until the courtesy light comes
on (approx. 5 seconds). On releasing the button the courtesy
light starts flashing.
1) After 4 seconds the operator automatically carries out closing
until detecting the ground stop.
2) The operator moves the door in opening. Wait until it reaches
the opening end travel or effect an OPEN command in the
position in which stopping of movement is required.
3) The operator closes the door.
4) Wait until the door reaches the ground stop and the operator
stops.
If the learning procedure was successful, the courtesy light stops
flashing and remains on for 5 seconds.
During these 5 seconds, in order to reduce the load on the re-
lease system, OPEN pulses can be sent within 2 seconds of each
other to reverse the carriage. A pulse equals 5 mm travel.
N.B.: Carriage reversing is only visible during normal operation
of the automatic system.
The electronic equipment establishes the deceleration points.
The pause time is set at 3 minutes.
MANUAL LEARNING WITH LOGIC "A" (AUTOMATIC)
Hold down the SET-UP pushbutton until the courtesy light comes
on (approx. 5 seconds). On releasing the button the courtesy
light starts flashing. Carry out the following procedure within 4 se-
conds (otherwise the operator carries out automatic SET-UP).
1) Effect the 1st OPEN command: the operator carries out a
closing operation until detecting the ground stop.
2) Effect the 2nd OPEN command: the operator carries out an
opening movement.
3) Effect the 3rd OPEN command to establish the point at which
the start of deceleration is required.
4) Effect the 4th OPEN command to establish the point of stop-
ping in opening, or wait until the automatic system detects
the opening end travel. After stopping, the count of time
when the automatic system is left open begins. This is the
pause that will be respected in normal operation (max. 3
minutes).
5) Effect the 5th OPEN command: the pause time count is
stopped and the closing movement starts.
6) Effect the 6th OPEN command to establish the point at which
the start of deceleration is required.
7) Wait until the door reaches the stop and the operator
stops.
If the learning procedure was successful, the courtesy light stops
flashing and remains on for 5 seconds.
During these 5 seconds, in order to reduce the load on the re-
lease system, OPEN pulses can be sent within 2 seconds of each
other to reverse the carriage. A pulse equals 5 mm travel.
N.B.: Carriage reversing is only visible during normal operation
of automatic system.
LEARNING WITH THRUST FORCE 1000N (G100 only)
If learning is not carried out correctly due to heaviness of the
door or for problems in moving it, learning can be carried out
with an increased thrust force (1000N max. thrust instead of
600N).
To launch this type of learning:
1) Start the required learning cycle in the usual way.
2) While the automatic system is executing the required mo-
vements, repeat the launch of learning procedure.
3) The automatic system starts the learning cycle again, but
with increased thrust.
MANUAL SETTING OF GROUND STOP
During the learning phase, the operator seeks the ground stop
using the maximum deliverable force (600N for the G60, 600
or 1000N for the G100). To avoid excessive stress, the stopping
point can also be established manually: when the automatic
system executes the closing movements, effect an OPEN
command when the stop is reached, If the stop commands
are incongruous at the first and second closing, the automatic
system will signal anomaly status and the learning cycle will
have to be repeated.
N.B.: at the end of the learning cycle make the automatic system
do a complete cycle to allow it to acquire the correct stopping
point in closing. After this cycle, if the automation reopens the
door again, command its closing.
N.B.: The sensitivity of the anticrushing device depends on the
programming (anticrushing sensitivity, manual force adjust-
ment) and the mechanical characteristics of the door. After
installation and programming, always carry out the checks
required by the rules given in the chapter "INSTRUCTIONS FOR
THE INSTALLER" of this handbook.
PRE-FLASHING
The pre-flashing function can be activated and disabled (fol-
lowing an OPEN command, the unit ctivates the flashing lamp
for 5 seconds before it starts the movement). Procedure:
1) Press and hold down the SETUP key.
2) Press the OPEN key too after about 3 seconds. If the courtesy
lamp goes ON, pre-flashing was activated, if instead, it stays
OFF, pre-flashing was disabled.
3) Release both push-buttons.
22
ENGLISH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G100

Tabla de contenido