Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7 Operation

6.6 Feed in wire

7 Operation
EN - 12
NOTE
• Make all shielding gas connections gas-tight.
 See Fig. 3 Mounting the cable assembly on the machine side on
page EN-10
1 Connect shielding gas cylinder (4) to the wire feeding unit (6).
2 Set the gas quantity on the pressure reducer of the shielding gas cylinder
(4).
NOTE
• Each time the wire is changed, make sure that the cutting point is free of
burrs.
1 Insert the wire in the wire feed unit (6) as specified by the manufacturer.
2 Press the "Wire Jog" push-button at the wire feed unit (6) until the wire
comes out of the contact tip.
DANGER
Shortness of breath and poisoning caused by inhaling
phosgene gas
During the welding of work-pieces that have been degreased with chlorine-
containing solvents phosgene gas is formed.
• Do not inhale fumes and vapours.
• Ensure sufficient supply of fresh air.
• Rinse work-pieces with clear water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
MAG

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aut 610d

Tabla de contenido