2. Test each of the functions.
9

Transport and storage

9.1
Transport
Do not attempt to carry the device when it is full of waste material.
Do not attempt to crane-lift the device.
▶ Remove the power conditioner and all loose accessory tools from the cradle.
▶ Empty the device before carrying it to another location.
▶ Do not tilt the device or transport it lying on its side after using it to pick up liquids.
▶ Use the tapered adapter to connect both ends of the hose together conveniently for transport.
VC 20M-X
VC 40M-X
M-class vacuum cleaners
DANGER
Risk of injury. Hazardous material that has been picked up may escape through the suction hose inlet
socket.
▶ Close the intake fitting on a class H or class M vacuum cleaner with the cap provided before
transportation and when the appliance is not in use.
9.2
Securing cases
1. Make sure that the vacuum cleaner is standing firmly and apply the holding brake. Pull the transport
handle all the way out.
2. Position one or more cases on the vacuum cleaner.
▶ It is not permissible for the case/cases to project above the transport handle.
▶ Do not exceed the maximum permissible weight for additional load.
3. Pull the lashing strap out of the holder and over the cases. Extend the lashing strap as necessary.
4. Engage the hook of the lashing strap on the transport handle and tighten the lashing strap.
9.3
Storage
▶ Store the vacuum cleaner in a secure, dry place where it is inaccessible to unauthorized users.
10
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
10.1
Malfunction, vacuum cleaner
Malfunction
Change filter service indica-
tor lights up.
The appliance doesn't start or
switches itself off after a short
time.
*2268215*
7
Possible cause
Filter element is clogged or too old. ▶ Check the fill level in the waste
No filter element inserted.
The water level cut-out is acti-
vated.
2268215
Action to be taken
material container.
▶ Press the Manual cleaning
operating button. → page 24
▶ Change the filter, if necessary.
→ page 30
▶ Insert a suitable filter element.
→ page 30
▶ Clean the sensors and the
area around the sensors with a
brush.
English
31

Publicidad