3. Technical data
(continuation)
General torch data with reference to EN 60 974-7
Type of voltage:
Electrode polarity:
Wire type:
Type of guide:
Voltage measurement:
Connection protection
Machine side (EN 60 529):
Shielding gas:
Product specific torch data as laid out in 60 974-7
MB.../AUT.../RAB... version
Type
Type of
Rating
cooling
CO
(A)
14
air
160 140 60
15
air
180 150 60
25
air
230 200 60
24
air
250 220 35
26
air
230 200 35
36
air
300 270 60
38
air
350 320 35
40
air
350 320 35
240 D
liquid 300 270 100 0.8 - 1.2
401 D
liquid 400 350 100 0.8 - 1.2
401
liquid 450 400 100 0.8 - 1.2
501 D
liquid 500 450 100 1.0 - 1.6
501
liquid 550 500 100 1.0 - 1.6
602
liquid 600 550 100 1.0 - 1.6
PP...-Version
24
air
230 200 60
26
air
240 220 60
36
air
290 260 60
240 D
liquid 270 240 100 0.8 - 1.2
401 D
liquid 350 320 100 0.8 - 1.2
When pulse arc welding the load data may be reduced by up to 30 %.

Cable assembly

Standard length L:
- by PP-Version:
Coolant connection:
Cooling unit performance:
Standard-control cable:
D. C. voltage
Positive as a rule
Standard round wire
manual
Peak value of113 V Peak value of141 V
IP3X
CO
or M21 mixed gas in compliance
2
with DIN 439
D.C
Wire-dia.
M21
2
(A)
(%)
(mm)
0.6 - 0.9
0.6 - 1.0
0.8 - 1.2
0.8 - 1.2
0.8 - 1.2
0.8 - 1.2
1.2 - 1.6
1.0 - 2.4
0.8 - 1.2
0.8 - 1.2
0.8 - 1.2
3.00 m / 4.00 m / 5.00m
at 8.00 m
NW 5 connector nipple
min. 800 W
2-pole
automatic
IP2X
Gas flow
Cooling data
rate
max.
min.
Flow pressure
feed-
flow-
min.
temp. rate
(l/min)
(°C)
(l/min) (bar)
10 - 18
10 - 18
10 - 18
10 - 18
10 - 18
10 - 20
10 - 20
10 - 20
10 - 20
50 1
2.0
10 - 20
50 1
2.0
10 - 20
50 1
2.0
10 - 20
50 1
2.0
10 - 20
50 1
2.0
10 - 20
50 1.3 2.0
10 - 18
10 - 18
10 - 20
10 - 20
50 1
2.0
10 - 20
50 1
2.0
17
max.
(bar)
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

Publicidad