Mounting The Cable Assembly; Setting The Shielding Gas Quantity - Abicor Binzel RB/RP Serie Instructivo De Servicio

Mag antochas de soldadura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAG Welding torches

4.3 Mounting the cable assembly

4.4 Setting the shielding gas quantity

10Screw in gas diffuser (1), tip adaptor (11) and contact tip (9) and attach
gas nozzle (10).
1 Connect Euro plug and adaptor kit at the wire feed unit and secure them
with the retention nut.
2 Properly mount the connections for water supply/return, shielding gas and
control line plug.
NOTE
• Check the minimum coolant level of the cooling device.
• Make sure that the coolant supply and return have been installed
properly. Coolant supply = blue, Coolant return = red.
• Do not use any deionized or demineralized water as coolant or for
tightness or flow tests.
This may impair the service life of your welding torch.
• Each time the device is commissioned or after each hose assembly
change, the cooling system must be ventilated as follow: disconnect the
coolant return hose from the re-circulating cooling unit, and hold it over a
collecting device. Close the opening at the coolant return hose. Open it
again by repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles.
• We recommend the use of ABICOR BINZEL series BTC coolant for
liquid-cooled welding torches.
NOTE
• The type and quantity of the shielding gas quantity depends on the
welding task and the gas nozzle geometry.
• To prevent the shielding gas supply from becoming clogged by
impurities, the cylinder valve must be opened briefly, before connecting
the cylinder. This will blow out any impurities that may be present.
• Make all shielding gas connections gas-tight.
4 Putting into operation
EN - 7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rb/rp 61gdRb/rp 610d

Tabla de contenido