6 Putting into operation

6.5 Connecting the cable assembly

6.6 Mounting the machine side connection
6.7 Mounting the wire conduit and liner
1
Guide tube
2
Wire conduit
3
Nut
Fig. 7
Mounting the wire conduit and liner
EN - 14
9 Unscrew knurled screw (11) enough to allow the cold-wire feeder (12) to
be swung out laterally.
10Screw nozzle (13) onto cold-wire feeder.
11 Position cold-wire feeder (12) and tighten knurled screw (11).
CAUTION
Mechanical hazard
A loose torch body can result in a mechanical hazard.
• Check the fastening of the torch body and the cable assembly.
1 Join welding cable plug and socket at the power supply and lock them.
2 Connect Emergency Stop cable, pilot and power supply.
7
6
4
Retaining nipple
5
Guide
NOTE
• Install the wire guide continuously to the torch, to avoid possible faults
and errors.
1 Guide sharpened liner through wire conduit (2).
1
5
6
7
®
ABIPLAS
WELD CT
2
3
4
Cold-wire tube
Feeding nozzle