11
TECHNICAL SPECIFICATIONS
11
Technical specifications
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Output current I
max.
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit value; residual ripple max. 5 V
With light / dark ratio 1:1
3)
4)
Signal transit time with resistive load
5)
A = U
-connections reverse polarity protected
B
C = Interference suppression
D = outputs overcurrent and short-circuit protected
11.1
Dimensional drawing
10
ss
14
(0.55)
5.5
(0.22)
Ø 2.3
(0.09)
Figure 6: Dimensional drawing GTE2F
GTE2F-Xxx11
2 ... 12.5 mm
1.5 ... 15 mm
7.5 mm / 10 mm
DC 10 ... 30 V
≤ 50 mA
800 Hz
3)
≤ 0.625 ms
IP67
III
A, C, D
5)
-20 °C ... +50 °C
3.5
1
(0.14)
(0.04)
Ø 2.2
(0.09)
2.2
(0.09)
GTE2F-Xxx31
2 ... 25 mm
1 ... 30 mm
1)
1)
5.5 mm / 15 mm
DC 10 ... 30 V
2)
2)
≤ 50 mA
800 Hz
3)
≤ 0.625 ms
4)
4)
IP67
III
A, C, D
5)
-20 °C ... +50 °C
8025415 | SICK
Subject to change without notice