Disassembly and disposal

9

Maintenance

10

Technical specifications

Recommended sensing range for the best performance
Sensing range max.
Light spot size / distance
Supply voltage U
B
8025299.1DTW /2022-02-14 | SICK
Subject to change without notice
LED/fault pattern
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
No object in beam path, no
output signal
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces using a plastic cleaner, do not use acetone or methy‐
lated spirits.
Check the fittings and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
Cause
The sensing range distance is
too large
Distance between the sensor
and the object is too long or
sensing range is set too short
Test input (Test) is not con‐
nected properly
WTB4FP-xxxxx1
WTB4FP-xxxxx2
40 mm ... 140 mm
30 mm ... 60 mm
4 mm ... 220 mm
1)
4 mm ... 100 mm
(Typ)
Ø 4,5 mm (160
Ø 2 mm (50 mm)
mm) (Typ)
(Typ)
DC 10 ... 30 V
DC 10 ... 30 V
2)
O P E R A T I N G I N S T R U C T I O N S | WTB4F
Measures
Reduce the sensing range
Increase the sensing range
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
WTB4FI-xxxxx1
40 mm ... 160 mm
6 mm ... 250 mm
(Typ)
Ø 4.4 mm (130
mm) (Typ)
DC 10 ... 30 V
2)
2)