HVU M16 INSTALLATION DATA (IN MM)
Minimum thickness of suport
Drilling diameter
Maximum clearance diameter
Minimum drilling depth
Implantation depth
Minimum distance between
centres of fixing points
Minimum distance between free
edge and fixing point
Tightening torque
HVU M12 / HAS-R M12 INSTALLATION INSTRUCTIONS
(following the installation data given above)
Drill the hole perpendicular to the support
Remove the concrete debris with a brush then
remove the dust
Insert the whole of the HVU plug into the hole or fill
it with resin
Insert the threaded rod using a percussion
screwdriver in order to crush and mix the chemical
compound
3 - USE

3 -1 USEFUL INFORMATION

To correctly attach the fall arrest harness to the anchor point (fulfilling EN 795)
and limit a dangerous fall or restrict the height of a fall, we recommend:
• connecting a shock absorber (fulfilling EN 355) or automatic retractable
element (fulfilling EN 360) as a dorsal (back) connecting element for the body
harness,
• connecting an independent catching member including a locking element
(rigid, fulfilling EN 353-1, or flexible, fulfilling EN 353-2), as a front (chest)
connecting element for the body harness.
CARABINER
Connecting element fulfilling EN 362.
• The carabiner must be connected directly to the harness without an
intermediate element.
190
22
15
105
100
188
163
40 N.m (HILTI)
23

Publicidad