4 GETTING STARTED (continued)
4.5 SELECTING THE MEASUREMENT MODE - MTG4
The MTG2 has one measurement mode, 'Pulsed Echo'. The MTG4
has two measurement modes 'Pulsed Echo' and 'Echo-Echo
ThruPaint™'. For an explanation of the different modes, see
Table 1: Measurement Modes.
To select the measurement mode (MTG4), press Menu/Setup/
Reading/Measurement Mode.
Measurement
Mode
Pulsed Echo
(PE)
Echo-Echo
ThruPaint™
(EE)
Note: The
gauge should be re-calibrated when the measurement mode is changed -
see Section 7 'Calibrating your Gauge' on page en-8.
flash intermittently to indicate that re-calibration is required.
4.6 SELECTING THE MEASUREMENT UNITS
The gauges can display readings in mm or Inch. To select the
measurement units, press Menu/Setup/Units.
a
Thickness range is dependent on the material being measured and the transducer used.
en-5
R
TABLE 1: MEASUREMENT MODES
Icon
Description
The total thickness from the base of the transducer
to the material density boundary (typically the
back-wall) is measured. Suitable for measurement
of materials between 0.63mm and 500mm (0.025"
to 19.999") thick.
A coating of up to 2.0mm (0.08") thick is ignored
and the material thickness from the top surface of
the material to the material density boundary
(typically the back-wall) is measured. Suitable for
measurement of materials between 2.54mm and
20mm (0.100" to 0.787") thick.
a
a
The calibration icon will
www.elcometer.com