Working Instructions - Würth HLG 1600 BASIC Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
evice configurations
C0
Setting the temperature unit (°C or °F)
C1
Setting the lowest temperature
C2
Setting the highest temperature
C3
Setting the lowest air quantity
C4
Setting the highest air quantity
C5
Setting energy saving mode
Information
Once you have set a temperature or
air uantity in the device configurations
C1 to C4, the symbol
display, if you try to set a higher or lower
temperature or air quantity in level 2.
Setting device configurations C0 to C4
Press the selection button "".
Using button "+" or "-", select the desired tempera-
ture unit, temperature or air quantity.
Press the selection button "".
The temperature unit, temperature or air quantity
3
is saved.
Setting C5 device configurations
Press the selection button "".
Using button "+" or "-", select:
0 = Energy saving mode o
1 = Energy saving mode on
Press the selection button "".
If you have selected 1 (energy saving mode on),
"d 5" appears
Using button "+" or "-" set the time in seconds
after which the device switches to energy saving
mode when it is no longer moved.
The selection is saved.
3
Resetting device configurations
Set the switch [4] to level 0.
Press the "+" "" and "-" buttons simultaneously
and set the switch [4] to level 1 while maintaining
the buttons depressed.
All symbols appear on the display simultaneously.
3
The device configuration has been reset.
3
Memory locations 1 - 5
You can save up to 5 sets of settings (temperature
and air uantity).
Set the switch [4] to level 2.
Press the programming button "≡".
"1" appears in the display.
3
Set the desired temperature using the "+" and "-"
buttons.
Press the selection button "".
The temperature is saved.
3
Set the desired air quantity using the "+" and "-"
buttons.
Confirm with selection button "".
The air quantity is saved.
3
Press the programming button "≡" for at least two
seconds.
The desired temperature and air quantity are
3
saved in memory location 1.
Set other memory functions (2 to 5)
Press the programming button "≡" to go to the next
appears in the
memory function.
To set the temperature and air quantity proceed
as described above.
Removing the heat shield
When working in very tight spaces, the heat
shield [2] can be removed by turning.
To remove or attach the heat shield [2], switch the
device o and allow it to cool.
Setting the device down
Position the device on its support surfaces [3] to
allow it to cool down or so that both hands are
free when working.

Working instructions

CAUTION!
Risk of burns
There is an increased risk of burns
Â
when working without the heat
shield!
CAUTION!
Risk of burns
Burns can be caused by the hot
Â
nozzle or in the hot airflow.
Position the device on a level, stable
¾
surface and ensure that it cannot
topple over. Secure the cable outside
your area of work so that the device
cannot be knocked or pulled over.
15