Mimic panel
botton 0/1: to turn on and off (hold down for 2") and to exit from the menu during programming
Pressing brie y displays the set temperature and the working temperature; holding it down (hold for 2") allows you
to access various programming menus.
to increase the various settings
to decrease the various settings
Each time you press informs the memory of the electronic board that has been inserted into the 15Kg tank; a constant
pressure of 5"deletes Kg residues or those previously entered
(ventilation button) sets the operation of the fan as follows:
- Air OFF: no ventilation; the stove channels all the power to the water
- Air AUTO: ventilation is optimised by an automatic programme
- Air MAN 1-2-3-4-5: ventilation is chosen manually by the user using the slider-led
1
2
3
4
Filling the feed screw
If the pellet storage tank is completely emptied, it follows that
the Archimedes' screw is also emptied.
Before restarting the stove you must ll it by following these
steps: press the +/- keys simultaneously (via the remote control
or the synoptic panel) for a few seconds, after which, having
released the keys, the display will show the text "Reload".
It is quite normal for some pellet residue to remain inside the
hopper, this is what the feed screw is unable to pick up.
Once a month, fully vacuum the hopper to prevent dusty resi-
due from accumulating.
Automatic ignition
With the boiler-stove on stand-by, press the 0/1 button for 2
seconds (on the synoptic panel or remote control).
This will start-up the ignition process, 'Start-up' will appear on
the display and a countdown will commence in seconds (1020).
There is no preset time for the ignition process: its duration
will be automatically shortened if the control board detects that
certain tests have been carried out positively.
The ame appears after about 5 minutes.
INSTRUCTIONS FOR USE
Tap on the LED points to select the desired fan speed environment
5
Manual ignition (in case of start up failure)
At a temperature lower than 3 °C – too low for the electrical
resistance to become red hot - or if the resistance is temporarily
not working, you can use a relighter to ignite the boiler-stove.
Insert a well-lit relighter into the combustion chamber, close
the door and press 0/1 on the synoptic panel or remote control.
Operating modes
Operating from synoptic panel/remote control.
With the boiler-stove running or on stand-by, from the synoptic
panel.
Press the + or – keys to increase or decrease the desired water
temperature.
- Pressing the ventilation button causes the cyclic rotation of
the 3 different settings of the stove's internal ventilation system
(Air display).
You can turn the ventilation off (OFF), make it work in au-
tomatic mode (AUTO) or manually select the desired speed
(MAN: 1-2-3-4-5).
In either case (automatic or manual), ventilation is activated
when the stove is operational and automatically deactivates
when the stove is on stand-by.
- 47
-