We thank you for having chosen one of our products. GENIUS is
certain that from it you will obtain all the performance you require.
All our products are the result of years of experience in the field
automated systems, with the added advantage of being part of
one of the sector's leading groups.
Keep these instructions for future reference.
GENERAL SAFETY REGULATIONS
1. Do not pass while the leaves are moving.
2. Do not stop within the range of action of the leaves.
3. Keep all radio controls or other pulse emitters out of reach
of children.
4. Do not allow children to play with the automated system.
5. The automated system must not be used by children, persons
with limited physical and mental capacities or persons lacking
experience or the necessary training.
6. Do not voluntarily prevent movement of the leaves.
7. Ensure that branches or bushes do not interfere with leaf
movement.
8. Ensure that the system light signals are kept efficient and in
perfect view.
9. Manually move the leaves only after they have been released.
In case of malfunction, release the leaves to allow transit and
request the service of a qualified technician.
10. Do not modify any of the automated system components.
11. Request maintenance service every six months, as provided
for in current safety regulations.
OPERATION
The DIABLO automated system consists of an irreversible
electromechanical gearmotor housed in a corresponding
supporting box. The gearmotor is invisibly installed in the ground
and therefore does not affect the aesthetics of the gate. When in
rest position, the gate leaves are closed. When a pulse is sent,
the unit sets the motor in motion, which will begin to open the
leaves until opening is complete.
Once the opening phase is completed, if an automatic operation
logic has been selected, the unit will begin the pause-time count.
Once the set pause-time has expired, the unit commands the
gate to close.
If instead a semi-automatic operating logic has been selected,
once the opening phase is completed, a pulse must be sent to
close the leaves. For details on operating the gate and all the
installed accessories, please refer to the installation technician.
MANUAL OPERATION
1. Use the differential switch located upstream from the system
to cut off power.
2. Open the lock covering plug, ref. a.
3. Insert the key and turn it until it stops, ref. b.
4. Open the release lever, ref. c.
5. Manually move the leaf, ref d.
6. Place the release lever back in position.
1
3
RESTORING NORMAL OPERATION
1. Use the differential switch located upstream from the system
to cut off power.
2. Manually move the leaf until the release device engages,
ref. a.
3. Place the release lever in rest position, ref. b.
4. Turn the key until it stops, ref. c.
5. Close the protective plug, ref d.
6. Ensure that the leaf cannot be moved manually.
7. Power the system and perform a few cycles to ensure that the
automated system is operating correctly.
1
3
MAINTENANCE
Inspect the system every six months, as provided for in current
safety regulations.
This booklet contains a form for reporting servicing. Ensure that
it is completed in all its parts.
REPAIRS
Do not make any attempts at repairs and contact only qualified
GENIUS personnel and service centres.
SPECIAL APPLICATIONS
No special applications are provided for.
DIABLO