Technical Data; Measuring Ranges And Measurement Accuracy; 20 7.2 Trolley Dimensions And Weights; 20 7.3 Sensor Head - Bosch FWA 9000 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
7.

Technical data

7.1

Measuring ranges and measurement accuracy

Measurement options
Total toe (front axle + rear axle)
Individual toe (front axle + rear axle)
Camber (front axle + rear axle)
Setback (front axle + rear axle)
Geometrical driving axis
Castor
Toe-out on turns
Castor correction range (front axle)
Max. steering lock
(front axle + rear axle)
2) 3)
Wheelbase difference
Side offset left/right
Track width difference
Axle offset
¹
) Not for CCD 6cam wheel alignment units
2) For CCD wheel alignment units: Only in conjunction with electronic turntables
3) For 3D 8cam wheel alignment units: Not possible with all vehicles
7.2
Trolley dimensions and weights
Function
Dimensions H x W x D:
Weight
7.3
Sensor head

dimensions and weights

Function
Dimensions H x W x D:
Weight
7.4
Electrical cabinet dimensions and
weights
Function
Dimensions H x W x D:
Weight
7.5
Temperature and working environ-
ment
Function
Operating temperature
Storage temperature
Temperature gradient
Rel. humidity (operation)
Rel. humidity gradient
Max. operating height
Max. transportation height
Robert Bosch GmbH
Measurement accuracy
±4'
±2'
±2'
1)
±2'
±2'
±4'
±4'
±4'
±4'
±2'
±2'
±3'
±3'
Specification
1520 x 880 x 770 mm
ca. 110 kg
Specification
640 x 880 x 310 mm
21 kg
Specification
360 x 200 x 150 mm
5 kg
Specification
+10 °C - +40 °C
-5 °C - +60 °C
20 °C / hour
10 % - 90 % (40°C)
10 % / hour
-200 m - 3000 m
-200 m - 12000 m
Technical data | FWA 9000 | 27 | en
Within measuring range
±6°
±3°
±5°
±2°
±2°
±18°
±20°
±7°
±50°
±2°
±2°
±2°
±2°
7.6
Trolley power supply unit
Function
Input voltage
Input frequency
Power
7.7
Electrical cabinet 100 - 127 V
Function
Input voltage
Input frequency
Power
7.8
Electrical cabinet 220 - 240 V
Function
Input voltage
Input frequency
Power
7.9
Laser
Function
Wavelength
Pulse duration (main pulse)
Pulse energy (main pulse, overall projection)
Total measuring range
±18°
±9°
±10°
±9°
±9°
±22°
±20°
±10°
±60°
±2°
±9°
±18°
±9°
Specification
100 - 240 V AC (10 A)
50 - 60 Hz
0,35 KW
Specification
100 - 240 V AC (16 A)
50 - 60 Hz
2 KW
Specification
220 - 240 V AC
50 - 60 Hz
2 KW
Specification
808 nm
16 ms
12,8 mJ
|
1 690 906 002
2017-07-04

Publicidad

Tabla de contenido
loading

Tabla de contenido