Schumacher Electric PID-750 Manual Del Propietário página 9

Ocultar thumbs Ver también para PID-750:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM: Alarm is On
Reason/Solution
1. Display shows
mands too much surge power.
Cycle inverter power OFF and ON.
If problem persists, use a larger inverter or a
smaller device.
Remove defective device.
See warranty and call Customer Service
800-621-5485 (Hours: 7 a.m. – 4:30 p.m. CST).
2. Display shows
Recharge/replace low battery.
3. Display shows Voltage In between 10.5 and 11.0
Volts.
12 Volt battery is low.
Recharge/replace low battery.
Inverter will automatically shut off after battery volt-
age reaches 10.5 volts.
4. Display shows
If in a vehicle, repair/replace the alternator or
charging system.
Use a properly sized and rated 12 Volt battery.
If input voltage returns to 15 volts or less, the in-
verter will automatically restart.
TROUBLESHOOTING
SC
. Device has a short circuit or de-
Lo b
. 12 Volt battery too low.
Hi b
. 12 Volt voltage is too high.
8

Publicidad

Tabla de contenido
loading

Tabla de contenido