Apartment block 1 close
Apartment block 2 close
Hold-to-run close
stop
In this command category the user can select one of the operating modes specified in Table 1-E.
OPERATING MODE
stop
stop and brief inversion
photo
In this command category the user can select one of the operating modes specified in Table 1-F.
OPERATING MODE
stop and inversion
stop and brief inversion
stop
temporary stop
photo 1
In this command category the user can select one of the operating modes specified in Table 1-G.
OPERATING MODE
stop and brief inversion
12 – Robus 600-1000
This executes the sequence "close - close".
This executes the sequence "close - close". Important –
When sending a command, if the transmitter key is held down
for more than 2 seconds, the control unit activates a Stop.
The Closing manoeuvre is executed exclusively if the hold-to-
run command is used.
TABLE 1-E: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit re -
ceives the command, it stops the manoeuvre in progress
gradually and in a short time (not instantly).
When the control unit receives the "stop" command, it stops
the manoeuvre in progress and activates the application to
perform a brief inversion in the opposite direction.
TABLE 1-F: COMMAND CONFIGURATION
DESCRIPTION
Operating mode set in factory. When the control unit
receives the command, it stops the Closing manoeuvre in
progress and activates a total inversion (Opening). Caution! –
During execution of the Opening manoeuvre, this com-
mand is ignored.
When the control unit receives the command, it stops the
Closing manoeuvre in progress and activates the application
to perform a brief inversion in the opposite direction (Opening).
Caution! – During execution of the Opening manoeuvre,
this command is ignored.
When the control unit receives the command, it stops the
Closing manoeuvre in progress. Caution! – During execu-
tion of the Opening manoeuvre, this command is ignored.
When the control unit receives the command, it stops the
Closing manoeuvre for the entire time that the command
remains active. Otherwise, when the command is no longer
active, the control unit activates the application to perform an
Opening manoeuvre. Caution! – During execution of the
Opening manoeuvre, this command is ignored.
TABLE 1-G: COMMAND CONFIGURATION
DESCRIPTION
When the control unit receives the command, it stops the
Closing manoeuvre in progress and activates the application
to perform a brief inversion in the opposite direction (Opening).
Caution! – During execution of the Opening manoeuvre,
this command is ignored.