event log
This function enables the display of the events generated or received by the control unit. "Event" refers to a condition that
changes the operating status of the control unit, for example: activation of an input, end of a manoeuvre, activation of a photo-
cell or the alt input, etc. In this section the date and type of event can be displayed.
firmware updates
This function enables the firmware of a control unit to be updated with another compatible version, without the obligation to
change the board. To update, proceed as follows:
01. Download the firmware update file (the software update is available at the site internet www.nice-service.com);
02. In "Advanced Functions" select "Update firmware";
03. In the window displayed, select "Select file" and then select the update file previously downloaded. The data related to the
software of the device to be updated are displayed on the left of the window, while the data related to the update software and
compatible hardware versions are displayed on the right;
04. If the file is compatible, the text "Update firmware" appears on the button, and when this is clicked, the update procedure
is started. At the end of the procedure, if the message "Update completed successfully" is displayed, this means that the pro-
cedure has bee completed. Otherwise, the message "Retry" appears on the button; in this case press the button again to
repeat the update process.
If the update process is not completed, the user can retry a number of times, or return to the window "Device List", selecting
"Back" and then decide on how to proceed. In this window, the device previously selected will no longer be visible; to display
the latter select the down arrow on the right of the window and select the function "Devices in boot phase". This enables a
search for devices ready for the firmware update phase.
At this point the user can retry the update process, repeating the procedure described above.
If the update is still not completed successfully, contact the Nice Assistance Service.
user permits
This function enables the installer to decide which functions and parameters are to be selected for display and modifications by
the user. For example, for safety reasons, the installer can decide to prevent the user from modifying the parameters related to
automation motor force and speed.
User permits can be managed exclusively by using the "installer password" (password management, common functions).
Note – All parameters of the various functions of a control unit or receiver are factory set as disabled.