Nice Robus 600 Manual Del Usuario página 7

Ocultar thumbs Ver también para Robus 600:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
Partial open 1
Open
Close
Stop
High priority step step
Partial open 2
Partial open 3
Open and block
Partial open
program the required operating mode,
selecting in Table 1-B ("command con-
figuration" > "partial open" > operating
mode...)
Opening
program the required operating mode,
selecting in Table 1-C ("command config-
uration" > "opening" > operating mo de...)
Closing
program the required operating mode,
selecting in Table 1-B ("command config-
uration" > "closing" > operating mo de...)
Stop
program the required operating mode,
selecting in Table 1-E ("command con-
figuration" > "stop" > operating mode...)
Step step
program the required operating mode,
selecting in Table 1-A ("command con-
figuration" > "step step" > operating
mo de...)
Partial open
program the required operating mode,
selecting in Table 1-B ("command con-
figuration" > "partial open" > operating
mo de...)
Partial open
program the required operating mode,
selecting in Table 1-B ("command con-
figuration" > "partial open" > operating
mo de...)
Opening
program the required operating mode, se -
lecting in Table 1-C ("command configu-
ration" > "opening" > operating mo de...)
manoeuvre following the previous one (or still in
progress) according to the sequence of
manoeuvres as envisaged in the programmed
sequence.
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the
Opening manoeuvre until the position is
reached as set in the function "partial open
1"(Control unit functions > installation > posi-
tions > partial open 1).
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the
Opening manoeuvre until the opening limit
switch is reached.
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Clos-
ing manoeuvre until the closing limit switch is
reached.
Input configured as normally open.
When this command is sent, the control unit
stops the manoeuvre in progress gradually and
in a short time (not instantly).
Input configured as normally open.
When this command is sent, the control unit
activates the application to complete the next
manoeuvre following the previous one (or still in
progress) according to the sequence of ma -
noeuvres as envisaged in the programmed se -
quence.
Important – This command is performed even
if the control unit is set with the command
"block" (see Table 1).
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is rea ched as
set in the function "partial open 2" (Control unit
functions > installation > positions > partial
open 2).
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is reached as
set in the function "partial open 3" (Control unit
functions > installation > positions > partial
open 3).
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is reached as
set in the function "partial open 3"(Control unit
functions > installation > positions > partial
open 3).
Input configured as normally open.
Robus 600-1000 – 7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Robus 1000

Tabla de contenido