name
This parameter enables the user to assign the automation with a name other than the original, to facilitate identification (e.g.
northern gate").
A name comprising maximum 24 characters, including spaces, is admitted.
series
This parameter can be set with a value from 0 to 63; the factory setting is "0".
The series is a number that has to be assigned to each gearmotor, receiver or other device potentially connectable on a BusT4
network, to define its "classification area". Subsequently, when using automations in a complex system, all devices with the
same series number can be controlled simultaneously.
address
This parameter can be set with a value from 1 to 128; the factory setting is "2" for Receivers and 3 for Control Units.
The address is a number that has to be assigned to each gearmotor, receiver or other device potentially connectable on a
BusT4 network, to distinguish it from other devices in a series. Therefore all devices within a series must have a different
address from one another.
group
This parameter can be set with a value from 1 to 14, or "None"; the factory setting is "None".
The function enables the user to assign a number to a device to be controlled (for example a gearmotor or other device poten-
tially connectable to a BusT4 network), which enables this device to belong to a specific "command group".
Several devices, also if belonging to different series, can form part of the same group. Up to 14 groups of devices can be cre-
ated and, in particular, the same device may be inserted in 4 different groups.
In a device network, use of this function enables:
- simultaneous control of different devices inserted in a group, even if some of these belong to different series;
- use of a single receiver, installed in one of the devices belonging to the group, to control all the devices belonging to this group.
firmware version (not modifiable)
This function enables the display of the version of the firmware present in a device.
hardware version (not modifiable)
This function enables the display of the version of the hardware present in a device.
serial number (not modifiable)
This function enables the display of the serial number identifying a specific device. This number is different for each device, even
if of the same model.
password management
This function is useful to restrict access by unauthorised personnel to all or some of the programming functions of a device. If a
device is password protected, the user must perform the "log in" procedure to proceed with a programming session, followed
by the "log out" procedure on completion of the programming procedure. Note – the "log out" procedure enables the user to
prevent access by unauthorised personnel, by re-activating the existing password. Caution! – When programming the pass-
word on several devices (for example in Oview, the Control unit, Receiver etc.), we recommend using the same password for
all devices including Oview. This will avoid the need to repeat the login procedure each time the device is changed during use
of Oview and the connected Software.
Two types of password can be programmed on the devices (including Oview).
- the user password, comprising maximum 6 alphanumeric characters. Caution! – Do not use uppercase letters.
- the installer password, comprising maximum 6 alphanumeric characters. Caution! – Do not use uppercase letters.
2 – Robus 600-1000