COMMAND configuration
This item covers the command categories associable with inputs 1 - 2 - 3 (refer to the section "input configuration - Table 1"
to check the commands available). Each command category features various operating modes as described in a table (1-A, 1-
B, etc.):
step step
In this command category the user can select one of the operating modes specified in Table 1-A.

OPERATING MODE

Industrial mode
Open - Stop - Close - Stop
Open - Stop - Close - Open
Open - Close - Open - Close
Apartment block 1 step step
Apartment block 2 step step
Step Step 2
Hold-to-run
10 – Robus 600-1000
TABLE 1-A: COMMAND CONFIGURATION
DESCRIPTION
This executes the sequence "open in semi-automatic - close in
hold-to-run".
This executes the above sequence.
Operating mode set in factory (Input 1 - "step step" com-
mand). This executes the above sequence.
This executes the above sequence.
This executes the sequence "close - stop - open - open" un -
til the maximum opening position is reached. Note – If another
command is sent after this one, the application executes the
Closing manoeuvre with the same sequence.
This executes the sequence "close - stop - open - open"
until the maximum opening position is reached. Note – If
another command is sent after this one, the application exe-
cutes the Closing manoeuvre with the same sequence.
Important – When sending a command, if the transmitter key
is held down for more than 2 seconds, the control unit acti-
vates a Stop.
This executes the sequence "open - stop - close - open".
Important – When sending a command, if the transmitter key
is held down for more than 2 seconds, the control unit activates
a "partial open 1" command (input configuration > Table 1).
The Opening or Closing manoeuvre is executed exclusively if
the transmitter key is held down (hold-to-run).
When this command is sent, the control unit is
released (restoring normal operating status)
and activates the application to execute an
Opening manoeuvre.
Input configured as normally open.
When this command is sent, the control unit is
released (restoring normal operating status)
and activates the application to execute a
Closing manoeuvre.
Input configured as normally open.
This command enables the activation or deac-
tivation of the function for bluebus control pho-
tocells and inputs configured in "apartment
block open" mode. Note – the factory setting
of this function is "active".
For example, if this function is active, when the
control photocells are engaged, the control unit
activates the application to execute an Open-
ing manoeuvre.
Input configured as normally open.
This command enables deactivation of the "au t-
o matic opening active" mode described above.
Input configured as normally open.