III. USE OF THE LANCE
The high-pressure cleaner is supplied with five different
nozzle types:
- Low-pressure nozzle (fig. 3A, "CHEMICAL"): for
operating with detergent or cleaning with neg-
ligible pressure,
- 0° nozzle: straight stream (fig. 3B) for particu-
larly stubborn accumulation of grime,
- 15° nozzle: flat spray (fig. 3C) for dirt accumula-
tion over a large surface,
- 25° nozzle: flat spray (fig. 3D) for dirt accumula-
tion over a large surface,
- 40° nozzle: flat spray (fig. 3E) for dirt accumula-
tion over a large surface.
fig. 3A
fig. 3B
fig. 3C
IV. APPLIANCES PROVIDED WITH THERMAL VALVE
This device enables the machine's by-pass operation
through automatic water discharge whenever it reach-
es a temperature of nearly 60°C and cooling working
components.
CAUTION: appliances that are not provided with this
disposal must not operate for more than 2 minutes with
released gun. Recycled water raises its temperature re-
markably causing great damages to the pump.
MONTAGE
Study the series of photos shown below (fig.4):
OPERATING INSTRUCTIONS
CAUTION! Do not run the engine with a high or
low oil level as this can cause engine damage. If
fig. 4
fig. 3D
fig. 3E
you have further questions regarding the engine,
please refer to the engine's operating manual
included with the unit.
CAUTION! The engine is not provide with oil. It is
necessary to fil the carter before starting the en-
gine.
CAUTION! Before starting the pump, check the oil
level in the pump.
CAUTION! If it is the first time that you use the ma-
chine or if you do not operate the machine for a
long period, it is necessary to connect, for some
minutes, the suction hose, in order to let possible
impurities go out, so that the nozzle gun will not
become clogged.
CAUTION! Fill gas tank with unleaded gasoline.
Do not use leaded gasoline.
I. STARTING UP
WATER SUPPLY
Water supply connection - Additional safety infor-
mation
WARNING: (symbol) machine not suitable
for connection to the potable water mains.
CAUTION:
Water that has flown through backflow
preventers is considered to be nonpotable.
Caution - Danger!
Only clean or filtered water should be used for
intake. The water intake should be at least twice
the pump capacity.
- Minimum delivery rate: 15 l/min
- Maximum intake water temperature: 40°C
- Max inlet water pressure: 1Mpa
Place the cleaner as close as possible to the water sup-
ply.