The maintenance responsible must deactivate completely the machine, as here follow showed, before to proceed to the
fixed shelter removal and/or to the element change.
INSULATION FROM THE EXTERNAL FEEDING SOURCES
Before to perform any operation of maintenance, cleaning and parts change, the external feeling sources must be dissected
and insulated.
Position to "zero" the protection device placed to the bottom of the
electric equipment feeding line.
DAMAGES RESEARCH OR FAILURES AND MOBILE ELEMENTS UNBLOCK
Here follow are indicated he interventions for the damages research or failures and mobile elements unblock that can be
performed from maintenance men.
TYPE
POTENZIAL/S CAUSE/S
General black out
Net voltage
Fuses or magneto thermals intervention
lacking
placed to the bottom of the machine
feeding line
Protection device intervention inside the
machine
Pressure handle lifting (ELITE version:
Functioning
flashing green led)
intervention
Removel of the superior cover (ELITE
version: flashing red led)
Cause/s not identifiable
Feeding tension lacking (ELITE version:
all led switched off)
The machine
doesn't
Sectioning devices on "O" (ELITE
function: the
version: all led switched off)
discs don't
rotate or don't
Fuses intervened or not functioning
perform
magneto thermals.
correctly the
cutting
Lacked functioning of the run button
Micro switch damaged
Cutting discs worn or ruined
Slow drive belt determines also noise
emission or creaking
EXTRAORDINARY MAINTENANCE
For the intervention of extraordinary maintenance, consequent to breaks or revisions or mechanical and electric damages,
(for example the movement drive belts tensioning, etc...), it is necessary an intervention request directly to the Authorized
Assistance Centre.
The instructions about the extraordinary maintenance don't appear in the present instruction manual for the use and so
must be explicitly requested to the manufacturer.
Disconnect the general sectioning device and provide to protect the
plug with appropriate systems
MODALITY AND COMPARISONS
Contact the electric energy distributor.
After having eliminated the causes that have determined the protection device
intervention, restore it. In case of problem persistency contact an electrician
technician.
Contact an electrician technician: after to have eliminated the causes that have
determined the protection device interventions, restore it.
In case of fuses interventions, change it with types of the same model,
calibration and intervention curve.
Lifting the pressure handle, the machine stops immediately for the entrance in
function of the safety micro switch.
Lower the pressure up to the height that doesn't allow the fingers introduction
towards the cutting zone.
Removing the superior cover, the machine stops immediately for the entrance
in function of the safety micro switch.
Place correctly the superior cover and block it with the appropriate knob and
start the machine.
Contact directly the Authorized Assistance Centre
Check and restore the electric energy.
Turn the sectioning devices in the position "ON"
Make change the intervened fuses, check the magneto thermal switches
condition.
Check the efficiency of the button of "I" and eventually contact directly the
Authorized Assistance Centre.
Contact directly the Authorized Assistance Centre
Contact directly the Authorized Assistance Centre
Contact directly the Authorized Assistance Centre