Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
operation during cooking and for another 15 minutes
approximately after terminating cooking.

Control panel

1. Light Button
• Press lamp button to turn ON the light on High
Intensity (Lamp state previously OFF).
• Press lamp button to turn ON the light on Low
Intensity (Lamp state previously ON).
• Press lamp button to turn OFF the light (Lamp state
previously ON).
2. Timer Button
• The default timer setting is 10 minutes, and it can be
adjusted between 60 minutes and 1 minute.
• After pressing the timer button, the control enters to a
timer setup mode, and user can adjust the timer
countdown time with the "+" and "-" buttons within 5
seconds. The timer can be initiated immediately
pressing the timer button, after setting the timer
duration or pressing the timer button twice (default
10 minutes setting).
• If no action occurs within 5 seconds, the countdown
will start.
• During the timer setup the "+" and "-" buttons are
dedicated to the timer and no motor action will
occur.
• Once the timer is initiated, it can be cancelled by
pressing the timer button again.
3. Display
• Shows the hood settings.
• The display will be lit at low intensity when the hood is
not operating.
Pressing any key the display will light up at high
intensity.
• The display will be lit at high intensity when the hood
is operating.
If no key is pressed within a minute the display will
return to being lit at low intensity.
4. "-" Button. Speed Decrease / OFF
• This button is used to decrease the fan speed, or turn
OFF the fan.
• The fan will turn OFF if the "-" button is pressed and
the hood was in the first speed.
• If the fan is at second speed and the "-" button is
pressed, the fan will be set to first speed.
• If the fan is at third speed and the "-" key is pressed,
the fan will be set to second speed.
• If the fan is at fourth speed and the "-" button is
pressed, the fan will be set to third speed.
• If the fan is OFF and the "-" button is pressed, the
control backlight will light up.
5. "+" Button. Speed Increase / ON
• This button is used to increase the fan speed, or turn
ON the fan.
• The fan will turn ON if the "+" button is pressed and
the hood was OFF.
• If the fan is at first speed and the "+" button is
pressed, the fan will be set to second speed.
• If the fan is at second speed and the "+" button is
pressed, the fan will be set to third speed.
• If the fan is at third speed and the "+" button is
pressed, the fan will be set to fourth speed.
• If the fan is at fourth speed and the "+" button is
pressed, a beep will sound.
Clock programming
The clock can be reprogrammed at any time except
during an active timed function.
The clock can be displayed in a twelve hour format
and valid clock times are from 1:00 to 12:59.
The clock can be reprogrammed pressing the "Timer"
button for 3 seconds, and after, the clock can be
adjusted with the "+" and "-" buttons.
The user can have minute increments / decrements of
1 minute, but if the user keep pressing the "+" / "-"
buttons for more than 1 second, the increments /
decrements will be of 5 minutes.
During this option the control will round to the nearest
5 minutes.
The user can finish on reprogramming the clock
pressing the "Timer" button.
After 1 minute of no button pressed the control will
accept the programmed clock time and will add one
minute to the set clock.
Grease filter saturation alarm (Optional)
After thirty fan functional hours, the display will show
"Grease Filter" if the fan is active.
When this icon is shown in the display, the grease
filters installed are required to be washed.
To reset the grease filter saturation alarm the user
must press the "+" button for 5 seconds, after this
action the icon "Grease filter" is not displayed, and
the hood has the normal display operation.
Charcoal filter saturation alarm (Optional)
After one hundred and twenty functional hours of the
fan, the display will show "Charcoal Filter" if the fan is
active. When this icon flashes on display, the charcoal
filters installed are required to be replaced or
reactivated.
To reset the charcoal filter saturation indication the
user must press the "-" button for 5 seconds, after this
time the icon "Charcoal filter" is not displayed and the
hood has the normal display operation.