Decimals; Zero Level (Measuring Distance) - Orion Echo Manual De Instrucciones

Publicidad

2. Decimals

Go to this menu by using arrow keys and press E key. Enter value of decimal part of
the value measured by using up and down arrow keys. this value is a value between
0 and 3; and the part after dot defines decimal part.
• DECIMALS value for centimeter and inch can be selected as 1 maximum .
• If "VOLUME L" is selected from Type menu, DECIMALS can be selected as 1
maximum.

3. Zero level (Measuring Distance)

Go to this menu by using arrow keys and press E key, enter the level which will be
measured by using down and up arrow keys. (For example, depth of tank is 800 cm)
zero level is the distance from end of sensor to measuring base. Amount of liquid to
be measured is equal to difference of depth (zero level) and the distance from end
of sensor towards liquid surface.
Main Level = zero Level – distance
• Zero Level is a visible menu if LEVEL is selected from Type menu.
DISTANCE
ZERO
LEVEL
MAIN
18
 Orion Echo Ultrasonic Level Probe