4. Zero OFF (Measuring Offset)
Go to this menu by using arrow keys and press E key, enter the value by using down
and up arrow keys. It indicates the offset of the measured distance. the value
entered here is subtracted from measured distance and the Main distance becomes
calculated.
Main Dis= Distance − Zero Offset
• Zero OFF is a visible menu if Distance is selected from Type menu.
5. ınterval tPs
Go to this menu by using arrow keys and then press E key; enter frequency of signal
per second sent for measurement by using arrow keys. this value is between 1
and 8. It is a correct way to enter a value as per measured distance. (For example 1
measurement for 12 m and 4 measurements for 5 m etc.)
6. Filter (Filter settings)
Go to this menu by using arrow keys and press E key; you can change the number of
measurements to be added consecutively then divided into measurement number
by using down ad up arrow keys. Maximum 16 measurements can be taken into
average. For example, if a system taking one measurement per second is selected
as a foursome average, correct measurement score is seen on the screen and in the
outputs as one measurement per every 4 seconds.
7. span 4 and span 20
Go to this menu by using arrow keys and press E key; enter beginning and last
measurement value for 4 mA and 20 mA in analog output by using down and up
arrow keys. For example, if you do 40 cm as 4 mA and 400 cm as 20 mA for LEVEL
cM, your analog output becomes adjusted as 4-20 mA between 40 cm and 400 cm.
Orion Echo Ultrasonic Level Probe
19