command #19 Write Final Assembly number
request data bytes
response data bytes
response codes
common Practice commands
Command #33 Read Transmitter Variables
request data bytes
response data bytes
response codes
command #34 Write damping Value
request data bytes
response data bytes
response codes
command #35 Write range Values
request data bytes
response data bytes
response codes
#0 to #2 - Final Assembly number (24-bit unsigned int)
#0 to #2 - Final Assembly number
#0 - No Command-Specific Errors
#5 - too Few data bytes received
#0 Transmitter Variable Code For Slot 0 (See Varibale slot numbers in Table I)
#1 Transmitter Variable Code For Slot 1
#2 Transmitter Variable Code For Slot 2
#3 Transmitter Variable Code For Slot 3
#0 Transmitter Variable Code For Slot 0 (See variable slot numbers in Table I)
#1 Unit code For slot 0
#2 to #5 Variable For slot 0
#6 Transmitter Variable Code For Slot 1 (See Variable slot numbers in Table I)
#7 Unit code For slot 1
#8 to #11 Variable For slot 1
#12 Transmitter Variable Code For Slot 2 (See Variable slot numbers in Table I)
#13 Unit code For slot 2
#14 to #17 Variable For slot 2
#18 Transmitter Variable Code For Slot 3 (See Variable slot numbers in Table I)
#19 Unit code For slot 3
#20 to #23 Variable For slot 3
#0 - No Command-Specific Errors
#5 - too Few data bytes received
#0 to #3 Damping Value (Fixed 10)
#0 to #3 Damping Value (Fixed 10) as in command
#0 - No Command-Specific Errors
#5 - too Few data bytes received
#0 range Unit code
#1 to #4 Upper range Value
#5 to #5 Lower range Value
* same as in command *
#0 range Unit code
#1 to #4 Upper range Value
#5 to #5 Lower range Value
#0 - No Command-Specific Errors
#2 - Invalid Selection (wrong Unit Code)
#5 - too Few data bytes
#9 - Lower range Value too High
#10 - Lower range Value too Low
#11 - Upper range Value too High
#12 - Upper range Value too Low
#13 - Upper and Lower range Values Out of Limits
#14 - span too small
Orion Echo Ultrasonic Level Probe
239