Connections; Commissioning; Instructions For Use; Reminders For The User - Gastrodomus LM8T43 Instalación, Uso, Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
APPLIANCE ASSEMBLY WITH BASE, BRIDGE AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of
support utilized.
FIXING THE APPLIANCE TO THE FLOOR
If the appliance is installed alone, check if it needs to
be fixed to a top or to the floor. (TAB 5)
Secure the appliance to the floor one by one using
the adjustable feet, flanged or specific bracket
For single models refer to the technical data tables at
the bottom of this manual and to the Illustration
section.

6. CONNECTIONS

The position and dimensions of connections are given
in the installation diagram at the end of this manual.
ELECTRICAL CONNECTIONS
Check if the appliance is designed to operate at the
voltage and frequency of the power supply present
on site. Check the details given on the appliance
dataplate and plaque near the terminal board.
Install upstream of the equipment in an easily
accessible place, an all-pole disconnecting device with
a contact gap of allowing full disconnection under the
conditions of overvoltage category III.
A flexible rubber cable with insulation specifications
not lower than type H05 RN-F must be used for
connection.
Connect the power supply cable to the terminal
board as shown in the wiring diagram supplied with
the appliance.
Secure the power supply cable with the cable clamp.
Protect the power supply cable on the outside of the
appliance with a rigid plastic or metal pipe.
If the power supply cable is damaged, it must be
replaced by the manufacturer or his service centre or
by a person with similar qualifications to prevent any
risk.
THE SYMBOL " HIGH VOLTAGE" IS PLACED
ON A PANEL THAT GIVES ACCESS TO A
PART WITH HIGH VOLTAGE.
PROTECTIVE
EARTH
CONNECTIONS
AND
EARTH
BONDING
Connect the appliance to an efficient ground circuit.
Connect the earth conductor to the terminal with the
symbol next to the main terminal board.
Connect the metal structure of the appliance to the
equipotential node. Connect the conductor to the
terminal with the symbol placed on the outside of the
rear panel.

7. COMMISSIONING

ELECTRIC EQUIPMENT
Switch on the appliance as directed in the
instructions and reminders for use given in Chapter "
INSTRUCTIONS FOR USE " and check:
- the current values of each phase.
- the correct operation of the heating elements.

INSTRUCTIONS FOR USE

III.

8. REMINDERS FOR THE USER

READ THIS MANUAL CAREFULLY. IT
PROVIDES IMPORTANT INFORMATION
FOR SAFE INSTALLATION, USE AND
MAINTENANCE OF THE APPLIANCE.
THE MANUFACTURER WILL NOT BE LIABLE
FOR ANY DAMAGE OR INJURY RESULTING
FROM FAILURE TO OBSERVING THE
FOLLOWING RULES.
For after-sales service, contact technical assistance
centres authorized by the manufacturer and demand
the use of original spare parts.
Have the appliance serviced at least twice a year. The
manufacturer recommends taking out a service
contract.
The appliance is designed for professional use and
must be operated by trained personnel.
This equipment is designed for the food leavening . It
is designed for an industrial use. Other uses are
considered inappropriate.
Do not allow the appliance to operate empty for
prolonged periods. Only pre-heat the oven just
before use.
Do not leave the appliance unattended while in
operation.
In the event of an appliance fault or malfunction, shut
the gas shut-off valve and/or switch the appliance off
at the main switch installed upline.
Clean the appliance following the instructions given in
Chapter " INSTRUCTIONS FOR CLEANING".
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lm8t64Lm12t64Lm16t64

Tabla de contenido