BATTERY CHARGING TIMES
BATTERY
APPLICATION
POWERSPORTS
AUTOMOTIVE
300 CCA
1000 CCA
MARINE
Times are based on a 50% discharged
battery and may change, depending on age
and condition of battery.
ABORTED CHARGE
If charging cannot be completed normally,
charging will abort. When charging aborts,
the charger's output is shut off. The BAD
BATTERY (red) LED will light and the
CHARGING (yellow/orange) LED will
flash. The digital display will show an error
code (see the Troubleshooting section for
a description of the error codes). Do not
continue attempting to charge this battery.
Check the battery and replace, if necessary.
DESULFATION MODE
Desulfation could take 8 to 10 hours. If
desulfation fails, charging will abort. The
BAD BATTERY (red) LED wil light and the
CHARGING (yellow/orange) LED will flash.
COMPLETION OF CHARGE
Charge completion is indicated by the
CHARGED (green) LED. When pulsing,
the charger has switched to the maintain
mode of operation.
MAINTAIN MODE
(FLOAT-MODE MONITORING)
When the CHARGED (green) LED is
pulsing, the charger has started maintain
mode. In this mode, the charger keeps the
battery fully charged by delivering a small
current when necessary. If the charger has
to provide its maximum maintain current for
a continuous 12 hour period, it will go into
abort mode (see Aborted Charge section).
12. MAINTENANCE AND CARE
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
finished charging. Wipe off any battery
fluid that may have come in contact with
the clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the
finish shiny and help prevent corrosion.
CHARGING TIME (Hours)
SIZE
6A
8A
10A
6Ah
2
1. 5
1. 5
32Ah
5
4.5
4
4
3.5
3
10
8
7
50Ah
5
4
3.5
105Ah
11
10
8
This is usually caused by a drain on the
battery or the battery could be bad. Make
sure there are no loads on the battery. If
15A
there are, remove them. If there are none,
1
have the battery checked or replaced.
2
MAINTAINING A BATTERY
The SC4 charges and maintains 6 volt and
1. 5
12 volt batteries.
4
NOTE: The maintain mode technology
2
allows you to safely charge and maintain
a healthy battery for extended periods of
5
time. However, problems with the battery,
electrical problems in the vehicle, improper
connections or other unanticipated
conditions could cause excessive current
draws. As such, occasionally monitoring your
battery and the charging process is required.
USING THE BATTERY VOLTAGE TESTER
1. With the charger unplugged from the
AC outlet, connect the charger to the
battery following the instructions given
in previous sections.
2. Plug the charger AC power cord into
the AC outlet.
3. If necessary, press the BATTERY TYPE
button until the correct type is indicated.
4. Read the voltage on the digital display.
Keep in mind that this reading is only a
battery voltage reading; a false surface
charge may mislead you. Compare the
reading to the chart below.
6 V Battery
Voltage
Reading
6.4 or More
6.1 to 6.3
Less than 6.1 Less than 12.2
POWER-UP IDLE TIME LIMIT
If no button is pressed within 10 minutes
after the battery charger is first powered up,
the charger will automatically switch from
tester to charger if a battery is connected. In
that case, the charger will be set to charge
at the 3A rate and gel cell battery type.
• Coil the input and output cords neatly
when storing the charger. This will help
prevent accidental damage to the cords
and charger.
• Store the charger unplugged from the AC
power outlet in an upright position.
• Store inside, in a cool, dry place. Do not
store the clamps clipped together, on or
around metal, or clipped to the cables.
• 8 •
12 V Battery
Battery
Voltage
Condition
Reading
12.8 or More
Charged
12.2 to 12.7
Needs Charging
Discharged