9
Maintenance
Technical data
10
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Switching current (switching voltage)
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
Object with 90 % remission (based on standard
white DIN 5033)
2)
Limit value: operation in short-circuit protection
mains max. 8 A; residual ripple max. 5 Vss
3)
Limit values
Usage category to EN 60947-1 AC-15, DC-13
4)
5)
With light / dark ratio 1:1
Signal transit time with resistive load
6)
7)
Reference voltage DC 50 V
Rated voltage AC 250 V, overvoltage category 2
8)
9)
A = UV-connections reverse polarity protected
B = inputs and outputs reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit
protected
8015974.YVM5 | SICK
Subject to change without notice
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
WT23-2Xxx4x
100 ... 800 mm
50 ... 800 mm
1)
30 mm / 800
mm
DC 10 ... 30 V
2)
≤ 100 mA
200 Hz
5)
≤ 2.5 ms
6)
IP 65
II
7)
A,B,C,D
9)
-25 ... +60 °C
WT23-2P/Nxx2x WT23-2Sxx2x
100 ... 1000 mm 100 ... 1000 mm 300 ... 2000 mm
50 ... 1000 mm
50 ... 1000 mm
1)
50 mm / 800
50 mm / 800
mm
mm
DC 10 ... 30 V
2)
AC 90 ... 250 V
≤ 100 mA
3 A @ AC 250 V /
or DC 24 V
200 Hz
10 Hz
5)
5)
≤ 2.5 ms
6)
≤ 10 ms
6)
IP 65
IP 65
II
7)
II
8)
A,B,C,D
9)
A,C
9)
-25 ... +60 °C
-25 ... +60 °C
MAINTENANCE
WTE23-2
WTB23-2Xxx6x
300 ... 1100 mm
100 ... 1100 mm
50 ... 2300 mm
1)
1)
12 mm / 800
160 mm / 2000
mm
mm
3)
DC 10 ... 30 V
2)
DC 10 ... 30 V
≤ 100 mA
≤ 100 mA
4)
200 Hz
200 Hz
5)
≤ 2.5 ms
6)
≤ 2.5 ms
IP 65
IP 67
II
7)
II
A,B,C,D
9)
A,B,C,D
-25 ... +60 °C
-30 ... +60 °C
9
1)
1)
2)
5)
6)
7)
9)
7