Preparations before use
Read the Safety Recommendations before starting any work
Inspect all components for damage. Pay particular attention to high pressure pipes.
Damaged high pressure pipes must not be used and should be discarded
For mounting operations it is recommended to use oil with a viscosity of
approximately 300 mm
For dismounting operations, its is recommended to use oil with a viscosity of
approximately 900 mm
Use only clean oil. Dirty oil can permanently damage the internal workings of the
unit (see 4.4)
Fill the oil reservoir. Immerse the end in a container of clean oil. Pull the handle to
suck the oil into the reservoir.
Turn the reservoir upside-down and push on the
ball to remove any air from the reservoir
Screw the reservoir onto the injector,
air escapes from the nipple
NOTE:
The upper nut can be loosened to enable the reservoir
to be positioned. When in the desired position, tighten
the upper nut before screwing in the reservoir.
SKF THKI 300 / THKI 400
/s (1 400 SUS) at the operating temperature.
2
/s (4 100 SUS) at the operating temperature.
2
7