Graph of typical phase shift as a function of a 50 Hz AC primary current:
see appendices, page 61.
- Rise time from 10 to 90% Vs: ≤ 70 µs
- Fall time from 90 to 10% Vs: ≤ 70 µs
- Output noise:
from DC...1 kHz
from DC...5 kHz
from 1 Hz...5 kHz ≤ 500 µV rms or 0.5 A rms

Distortion parameters

I Maximum distortion of the frequency on the measurement (to be added to the error in the
reference range): 1% rdg from 65 to 440 Hz, 3.5% rdg from 440 to 2000 Hz and -3 dB to
10 kHz. See graph of typical error as a function of the frequency, in appendices, page 62.
I Battery voltage: ≤ 0.1% / V
I Temperature: ≤ 300 ppm /°C or 0.3% /10°C
I Humidity 10...85% RH at ambient temperature: ≤ 0.1% rdg
I Position of a conductor of ∅ 20 mm :
I Adjacent conductor carrying an AC current 50 Hz, at 23 mm from the clamp: < 10 mA/A
I Distortion of an external field of 400 A/m (50 Hz) on centred cable: < 1.3 A
I Common mode rejection: > 65 dB A / V
I Residual magnetism: < 4 mA/A

4.4/ MECHANICAL SPECIFICATIONS

- Watertightness: IP 40 in accordance with IEC 529
- Clamping diameter: 1 cable ∅ 39 mm (or 2 cables ∅ 25 mm)
1 busbar of cross section 50 x 12.5 mm
- Outside dimensions of clamp: 237 x 97 x 44 mm
- Fitted lead: 1.5 m
- Weight: 520 g
- Drop height : to IEC 68-2-32
- Protection from shocks : 100 g to IEC 68-2-27
- Vibrations : to IEC 68-2-6
≤ 1 mV or 1 A DC
≤ 1.5 mV or 1.5 A DC
from DC...440 Hz < 0.5%
from DC...1 kHz < 1%
from DC...2 kHz < 3%
from DC...2 kHz < 10%